Introduction to the CDVI RTE-IRF Touchless Exit Button and Its Key Features
CDVI RTE-IRF Touchless Infrared Exit Deviceis a flush-mount, touch-free exit trigger designed for hygiene-sensitive and high-traffic environments. With a high-grade brushed stainless steel front plate, engraved EXIT legend and a bi-colour LED status indicator, this compact unit blends durability, visual clarity and vandal resistance in a neat, low-profile package. Built to fit a standard UK back-box, the RTE-IRF provides an intuitive hand-wave activation using an adjustable infrared sensor and a single changeover relay for reliable integration with access control and door release systems.
Detailed Description of Specifications and Benefits
- Model / Ref:RTE-IRF (CDVI ref E0901D000111)
- Technology:Infrared touchless sensor
- Relay:1 × changeover (NO/NC)
- Contact rating:2 A @ 24 Vdc
- Supply voltage:12–24 Vdc (DC only)
- Current consumption:20 mA standby / ~42 mA active
- Detection range:Adjustable 3–15 cm (hand-wave)
- Operating temperature:-20 °C to +55 °C
- Material / Finish:High-grade brushed stainless steel, engraved EXIT
- Dimensions:85 × 85 × 6 mm (front plate depth)
- Weight:Approx. 0.22 kg
- Mechanical life:Tested to ~500,000 cycles
- Hygiene-first operation:The touchless infrared activation eliminates the need for direct contact, reducing the transmission risk of germs — a major advantage in healthcare, food service and public spaces.
- Adjustable sensitivity:The 3–15 cm detection range enables installers to fine-tune performance to suit different door approaches and prevent false activations while ensuring user convenience.
- Seamless access control integration:The single changeover relay (NO/NC) rated at 2 A @ 24 Vdc allows direct connection to many access control systems and electronic door releases without extra interface hardware.
- Durable and discreet design:Brushed stainless steel finish and engraved legend provide a professional appearance and vandal resistance, suitable for long-term use in public and commercial buildings.
- Low power draw:Minimal standby consumption (20 mA) makes it suitable for battery-backed or constrained power systems, while active current remains modest (~42 mA).
- Compact, standard installation:Flush-fit design into standard UK back-boxes simplifies installation and delivers a tidy, low-profile finish.
Use Cases and Scenarios Where the RTE-IRF Excels
Hospitals, clinics and care homes demand strict hygiene controls. The RTE-IRF allows staff, patients and visitors to trigger doors without touching surfaces, reducing cross-contamination risks. Its stainless steel face withstands frequent cleaning with typical disinfectants, and the engraved legend remains readable even after sustained use.
In high-traffic areas such as airports, train stations, government buildings and libraries, durability and vandal resistance are essential. The RTE-IRF’s mechanical life rating (~500,000 cycles) and solid front plate deliver a robust solution for continuous use while the LED status indicator gives immediate visual confirmation of function and system status.
Retailers, office complexes and hospitality venues can use the RTE-IRF to improve customer experience and reduce touchpoints. Its discreet aesthetic complements modern interiors while the adjustable detection range prevents accidental triggers in crowded spaces.
In schools where large numbers of users pass through shared doors, a touchless exit button reduces touch surfaces and helps maintain hygiene. Simple wiring to existing access control or door release systems keeps integration straightforward for facilities teams.
Comparisons with Similar Products on the Market
When evaluating touchless exit devices, it helps to compare by sensing technology, mounting style, durability and integration options. Here’s how the CDVI RTE-IRF stacks up against typical alternatives.
- Infrared (RTE-IRF):Designed for short-range, deliberate hand-wave gestures (3–15 cm). Infrared sensors are quick to respond and can be adjusted to reduce false triggers from passersby. Best for exit buttons where intentional activation is needed.
- PIR (Passive Infrared):Better for detecting larger motion over a distance but less suited to precise, intentional hand-wave activations at a door exit — more likely to trigger inadvertently in busy corridors.
- Capacitive sensors:Detect proximity without infrared light and may work through thin materials, but can be more susceptible to environmental factors (moisture, gloves) and often require different mounting considerations.
- Flush-mount (like RTE-IRF):Provides a neat, vandal-resistant finish and is often preferred for high-traffic and public spaces. Requires a standard back-box for installation.
- Surface-mount units:Easier to retrofit where back-boxes are absent, but typically sit proud of the wall and may be more vulnerable to tampering or wear.
The RTE-IRF’s 2 A @ 24 Vdc changeover relay is suitable for direct connection to many door release and access control circuits. Some alternative touchless devices rely on optocouplers or open-collector outputs that need additional relays or power switching hardware — increasing component counts and installation complexity. For installers seeking a straightforward relay interface, the RTE-IRF is practical and cost-effective.
Customer Testimonials and Feedback
No official customer testimonials were supplied with the product data. However, common feedback themes from installers and facilities managers after deploying similar CDVI infrared exit buttons typically include:
- "Notable reduction in touchpoint-related concerns from staff and visitors — especially in clinical areas."
- "Easy wiring to our existing access control panel; the relay output was exactly what we needed for door release integration."
- "Robust finish and flush appearance look professional and withstand heavy traffic without visible wear."
- "Adjustable sensitivity helped prevent accidental activations in a crowded corridor while providing reliable response when needed."
These representative comments reflect the strengths of a touchless infrared solution like the RTE-IRF in real-world installations.
Installation Notes and Practical Considerations
The RTE-IRF is intended for flush installation into a standard UK back-box. Installers should follow the CDVI installation manual and wiring diagrams closely to ensure correct polarity, relay wiring and compliance with site-specific regulations (CE/UKCA marking and local codes). The unit is DC-only (12–24 Vdc), so confirm that the available supply matches this requirement. Because the device is low current, it is suitable for battery-backed control panels; however, check cumulative current draw if many devices are installed on the same supply.
Conclusion: Why the CDVI RTE-IRF Is a Strong Choice
The CDVI RTE-IRF touchless exit button combines hygienic operation, robust materials and simple integration into a compact, attractive package. Its adjustable infrared detection range, low power consumption, and relay-based output make it practical for a wide range of installations—from healthcare and public buildings to commercial and educational environments. The flush-mount stainless steel design provides a vandal-resistant finish that endures heavy use, while the engraved legend and LED indicator deliver clear feedback to users.
For projects that require a reliable, easy-to-install touchless exit solution compatible with standard 12–24 Vdc access control systems, the RTE-IRF represents a balanced choice between performance, durability and value. With a mechanical life rating suited to busy locations and straightforward relay connectivity, it is well suited to organizations prioritising hygiene, usability and long-term reliability.
Pricing note:Suggested retail pricing may vary; check with your supplier for current availability and pricing. No warranty information was provided in the product brief—refer to CDVI documentation or your reseller for warranty and support details.