TwinflexPro² Two‑Wire 8‑Zone Fire Alarm Kit, 7 ASD Sounder Detectors & 2 Call Points 604-0008

Free Delivery 2‑Wire
2‑Wire 8‑Zone Fire Alarm Kit (604-0008)
About this product

Overview
The TwinflexPro² 604‑0008 boxed contractor kit is an 8‑zone two‑wire conventional fire alarm solution built around Twinflex Multipoint ASD detectors and the TwinflexPro² control panel. The system supports detectors, manual call points and sounders on a single two‑wire zone circuit to reduce installation time and cable runs.

  • Two‑wire (single pair) zone wiring supporting detectors, sounders and call points on the same circuit
  • Alarm confirmation / checkpoint technology for programmable pre‑alarm verification
  • 4×20 character backlit LCD with highlighted menu navigation and an event log of up to 500 events
  • Multipoint detectors with 7 selectable detection modes (3 smoke, 2 heat, rate‑of‑rise, combined smoke/heat)
  • RS‑485 interface for up to 8 repeater panels

What’s included

  • 1 × TwinflexPro² 8‑zone control panel (panel model referenced as 505‑0008)
  • 7 × Twinflex Multipoint ASD detectors with integral sounder
  • 2 × Twinflex manual call points
  • 1 × detector head removal tool
  • Note: panel requires 2 × 12 V sealed lead acid backup batteries (commonly 3.2–3.3 Ah) which are not always supplied with boxed kits

Use cases
Ideal for domestic, multi‑dwelling or small commercial communal installations where reduced wiring and clear alarm verification routines are beneficial. Suitable for contractors and installers seeking a compact 8‑zone boxed solution with integral logging and repeater capability.

Compliance & installation
Refer to the official Fike TwinflexPro² datasheet and installation manual for region‑specific certifications, EN54/CPR/UKCA markings and full wiring/commissioning instructions. Installation must be carried out by competent, certified personnel in accordance with local fire safety regulations and BS/EN standards where applicable.

FAST delivery by Order within
Ships from United Kingdom
Secure payment transactions
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Kit-contents
Part number
604-0008
Boxed kit includes
1× TwinflexPro² 8‑zone panel (505‑0008), 7× ASD sounder detectors, 2× call points, 1× detector removal tool
Batteries
Requires 2 × 12 V sealed lead acid (3.2–3.3 Ah recommended) - batteries not always supplied
Panel
Panel model
505-0008
Zones
8
Display
4 × 20 character backlit LCD
Event log
500 events
Repeater interface
RS‑485 (supports up to 8 repeaters)
Engineer's features
Man/walk test, 3 enhanced test modes, zone day/night configuration, programmable delays
Standby time
Up to ~72 hours (dependent on battery capacity and load)
Devices
Multipoint detectors
7 × Twinflex Multipoint ASD detectors with integral sounder
Detector modes
7 selectable modes (3 smoke, 2 fixed temp heat, rate‑of‑rise, combined smoke/heat)
Devices per zone
Up to 32 devices per zone
Detector sounder level
Typical 90 dBA (model/setting dependent)
Manual call points
2 × Twinflex manual call points
EOL
Built‑in end‑of‑line capability (no separate EOL resistor required)
Compliance
Standards
Documentation references EN54 / BS5839; consult Fike datasheet for exact CPR/EN54/UKCA markings
Datasheets & manuals
See manufacturer product‑documents page for TwinflexPro² (datasheet, manuals, DoPs)

Specifications

Kit-contents

Part number 604-0008
Boxed kit includes 1× TwinflexPro² 8‑zone panel (505‑0008), 7× ASD sounder detectors, 2× call points, 1× detector removal tool
Batteries Requires 2 × 12 V sealed lead acid (3.2–3.3 Ah recommended) - batteries not always supplied

Panel

Panel model 505-0008
Zones 8
Display 4 × 20 character backlit LCD
Event log 500 events
Repeater interface RS‑485 (supports up to 8 repeaters)
Engineer's features Man/walk test, 3 enhanced test modes, zone day/night configuration, programmable delays
Standby time Up to ~72 hours (dependent on battery capacity and load)

Devices

Multipoint detectors 7 × Twinflex Multipoint ASD detectors with integral sounder
Detector modes 7 selectable modes (3 smoke, 2 fixed temp heat, rate‑of‑rise, combined smoke/heat)
Devices per zone Up to 32 devices per zone
Detector sounder level Typical 90 dBA (model/setting dependent)
Manual call points 2 × Twinflex manual call points
EOL Built‑in end‑of‑line capability (no separate EOL resistor required)

Compliance

Standards Documentation references EN54 / BS5839; consult Fike datasheet for exact CPR/EN54/UKCA markings
Datasheets & manuals See manufacturer product‑documents page for TwinflexPro² (datasheet, manuals, DoPs)

2‑Wire 8‑Zone Fire Alarm Kit (604-0008) features

Fike 604-0008 Twinflex 8-Zone Fire Alarm Kit

TwinflexPro² Two‑Wire 8‑Zone Fire Alarm Kit, 7 ASD Sounder Detectors & 2 Call Points 604-0008

Introduction to the TwinflexPro Two‑Wire 8‑Zone Fire Alarm Kit

Product:TwinflexPro Two‑Wire 8‑Zone Fire Alarm Kit, 7 ASD Sounder Detectors & 2 Call Points (604-0008). This boxed contractor kit delivers a compact, installer‑friendly fire alarm solution for small commercial, multi‑dwelling and domestic communal applications. Built around the TwinflexPro control panel and Twinflex Multipoint ASD detectors, the 604-0008 kit reduces wiring complexity by supporting detectors, sounders and manual call points on a single two‑wire zone circuit while offering programmable alarm verification, an event history and repeater panel capability.

Key features at a glance

  • Two‑wire (single pair) zone wiring supporting detectors, sounders and call points on the same circuit to cut cable runs and installation time.
  • Alarm confirmation / checkpoint technology for programmable pre‑alarm verification to reduce false alarms.
  • 4×20 character backlit LCD with highlighted menu navigation and an event log storing up to 500 events.
  • Twinflex Multipoint ASD detectors (7 units) offering 7 selectable detection modes: 3 smoke, 2 fixed temperature heat, rate‑of‑rise and combined smoke/heat.
  • Supports up to 8 zones and up to 32 devices per zone; RS‑485 interface supports up to 8 repeater panels.

Detailed specifications and benefits

The TwinflexPro 604-0008 kit is supplied as a boxed contractor package and includes the 8‑zone control panel (panel model 505-0008), seven Twinflex Multipoint ASD detectors with integral sounders, two manual call points and a detector head removal tool. Note that the panel requires two 12 V sealed lead acid batteries (commonly 3.2–3.3 Ah) which are not always supplied with the boxed kit.

  • Eight zones:Useful segmentation for small buildings, allowing separate alarm circuits for flats, corridors, plant rooms or common areas.
  • Display and logging:The 4×20 character backlit LCD with highlighted menu navigation makes commissioning and fault finding fast; the 500‑event log provides a useful audit trail for service records and investigations.
  • Engineer tools:Man/walk test modes, three enhanced test modes, configurable zone day/night profiles and programmable delays provide flexibility for commissioning and maintenance.
  • Repeater capability:RS‑485 interface supports up to eight repeaters for remote annunciation of panel status in larger or multi‑entrance properties.
  • Multipoint ASD detectors:Each of the seven detectors supports seven selectable detection modes. This multipoint capability helps installers tailor sensitivity and behaviour to the environment (e.g. smoke‑sensitive corridors vs heat‑sensitive kitchens).
  • Integral sounders:Detectors include sounder capability (typical ~90 dBA depending on model/setting), allowing notification appliances to be distributed without separate sounder wiring.
  • Two‑wire simplicity:Detectors, manual call points and sounders share a single pair per zone. The built‑in end‑of‑line arrangement removes the need for separate EOL resistors, saving time and material costs.
  • Device density:Up to 32 devices per zone provides headroom for future expansion within the 8‑zone architecture.

Use cases and scenarios where the TwinflexPro excels

The 604-0008 kit is designed for projects where simplicity, cost‑effective cabling and flexible detection modes matter. Typical installations include:

  • Small commercial premises:Shops, offices, small warehouses and community centres where an 8‑zone conventional system covers all required areas without the complexity of addressable loops.
  • Multi‑dwelling and communal living:Apartment blocks, sheltered housing and student accommodation benefit from reduced cable runs between flats and common areas, plus the multipoint detector modes allow tailoring to kitchens, corridors and communal lounges.
  • Refurbishment and retrofit:Two‑wire wiring reduces the need to chase walls or add new containment when upgrading older conventional systems; the integral sounder detectors also cut additional wiring for notification devices.
  • Contractor boxed solution:For installers wanting a compact, tested kit rather than multiple components, the 604-0008 provides a near‑complete package—only the backup batteries are commonly added separately.

Comparisons with similar products and system types

When selecting a fire alarm solution, buyers commonly compare two‑wire conventional kits, standard multi‑wire conventional systems, addressable systems and wireless options. The TwinflexPro 604-0008 sits in the two‑wire conventional category and stands out for several reasons:

  • Cabling efficiency:Traditional conventional systems often require separate sounder circuits and call point wiring; the TwinflexPro’s two‑wire approach places detectors, sounders and call points on one pair per zone, significantly simplifying installation and reducing labour and material costs.
  • Commissioning speed:Fewer conductor runs and built‑in EOL capability accelerate commissioning and fault diagnosis.
  • Cost and complexity:Addressable systems offer pinpoint device identification and sophisticated mapping but carry higher hardware and programming overheads. For small sites where per‑device identification isn’t required, TwinflexPro delivers much of the practical functionality (event logging, repeater use, configurable detector modes) at a lower cost and with simpler maintenance.
  • Scalability:Addressable panels scale to hundreds of devices; the TwinflexPro is ideal where eight zones and up to 32 devices per zone are sufficient.
  • Reliability and lifetime:Wired two‑wire systems are generally favoured where signal reliability and long‑term maintenance predictability are priorities; wireless can be attractive for hard‑to‑cable locations but requires battery management and often has higher per‑device costs.

Customer feedback and installer impressions

At the time of publication there are limited verified end‑user testimonials published specifically for the 604-0008 boxed kit. However, installer and contractor communities typically comment positively on the TwinflexPro family for the following practical reasons:

  • Time savings from single‑pair zone wiring and integrated EOL reduce on‑site labour.
  • Multipoint detector modes allow tailored sensitivity, lowering nuisance alarms in mixed environments (kitchens, corridors, plant rooms).
  • Compact boxed kits reduce procurement overhead and ensure component compatibility out of the box.

When evaluating feedback, look for independent installation case studies and request references from suppliers to confirm performance in environments similar to your project.

Practical considerations before purchase and installation

  • Batteries:The panel requires 2 × 12 V sealed lead acid batteries (3.2–3.3 Ah recommended). Confirm whether your boxed kit includes them or budget to supply separately.
  • Regulatory compliance:Refer to the official Fike TwinflexPro datasheet and installation manual for region‑specific certifications (EN54/CPR/UKCA) and ensure installation by appropriately qualified personnel following local standards such as BS/EN requirements.
  • Expansion and repeaters:If you anticipate the need for remote annunciation, the RS‑485 repeater support for up to eight repeaters is a useful feature—confirm repeater models and wiring plans at design stage.

Conclusion: why TwinflexPro 604-0008 is a strong choice

The TwinflexPro Two‑Wire 8‑Zone Fire Alarm Kit (604-0008) is a practical, installer‑friendly solution for small commercial, multi‑dwelling and retrofit projects where reduced wiring, programmable detection behaviour and clear event logging are priorities. Its two‑wire architecture and integral sounder detectors simplify installation and reduce labour, while the multipoint detector modes and confirmation technology help manage nuisance alarms without sacrificing safety. The 4×20 LCD and 500‑event log provide useful operational transparency for engineers and building managers, and RS‑485 repeater support adds flexibility for remote annunciation.

For contractors seeking a compact boxed kit that balances capability and cost, the 604-0008 offers a compelling middle ground between basic conventional systems and more complex addressable solutions. As always, confirm the product’s certification and enlist qualified installers to ensure compliance with local fire safety regulations and standards.

Fike 604-0008 Twinflex 8-Zone Fire Alarm Kit
Dynamic CCTV New

TwinflexPro² Two‑Wire 8‑Zone Fire Alarm Kit, 7 ASD Sounder Detectors & 2 Call Points 604-0008

£520.93 £632.91

Overview
The TwinflexPro² 604‑0008 boxed contractor kit is an 8‑zone two‑wire conventional fire alarm solution built around Twinflex Multipoint ASD detectors and the TwinflexPro² control panel. The system supports detectors, manual call points and sounders on a single two‑wire zone circuit to reduce installation time and cable runs.

What’s included

Use cases
Ideal for domestic, multi‑dwelling or small commercial communal installations where reduced wiring and clear alarm verification routines are beneficial. Suitable for contractors and installers seeking a compact 8‑zone boxed solution with integral logging and repeater capability.

Compliance & installation
Refer to the official Fike TwinflexPro² datasheet and installation manual for region‑specific certifications, EN54/CPR/UKCA markings and full wiring/commissioning instructions. Installation must be carried out by competent, certified personnel in accordance with local fire safety regulations and BS/EN standards where applicable.

Default

  • -
View product