Supplying the West Midlands with electronics since 1975. Learn more

Zeta / T2 Mains Safety Isolator Switch 400-210R, Keylock Double-Pole 4A

Lockable
Fire Alarm Mains Isolator (4A, Keylock)
About this product

Zeta / T2 400-210R Mains Safety Isolator Switch — tamper‑resistant, key‑operated local isolator for fire alarm control and indicating equipment. Designed for professional installations where a secure, lockable local isolation point is required for maintenance and safety.

  • Double‑pole isolation (switches Live and Neutral) for safe local isolation.
  • Integral internal fuse (not removable without opening the cover).
  • Keylock actuator — key removable in both ON and OFF positions to prevent unauthorised switching.
  • Neon indicator to show mains present at switched output.
  • Single‑gang format suitable for surface or backbox mounting; typically supplied in red (400-210R).

Where this is used: Installed adjacent to fire alarm control and indicating equipment (CIE) to permit safe isolation for maintenance or servicing. Labelled "FIRE ALARM — DO NOT SWITCH OFF" in line with common site practice.

Compliance & safety: Manufacturer references CE documentation and cites compatibility with BS5839 installations — consult the manufacturer datasheet and local regulations before installation. Must be installed by a qualified electrician. Do not switch off except by authorised personnel; observe all site safety procedures.

Note on pricing: Cost price provided = 15.36 (currency not specified). Suggested price shown on this record assumes a 16% minimum gross margin and uses the numeric cost value supplied; confirm currency and whether prices should include VAT or other tax for final RRP.

FAST delivery by Order within
Ships from United Kingdom
Secure payment transactions
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Technical
Model / SKU
400-210R
Switch rating
4 A @ 250 VAC
Poles
Double‑pole (L & N)
Fusing
Internal fuse (requires cover removal to access)
Indicator
Neon mains‑on lamp (switched output)
Key operation
Keylock actuator; key removable in ON & OFF
Label
Usually marked 'FIRE ALARM — DO NOT SWITCH OFF'
Colour
Typically red (400-210R); white version (400-210W) available where offered
Mounting
Single‑gang enclosure; surface/backbox fit
Physical
Enclosure
Single‑gang format
Dimensions
INSUFFICIENT DATA
Material
INSUFFICIENT DATA
Weight
INSUFFICIENT DATA
Standards-&-approvals
Standards
Manufacturer references use with BS5839 systems
Certification
CE certificate/datasheet available from manufacturer (see datasheet)
Installation note
Fit by qualified electrician; follow local regulations

Specifications

Technical

Model / SKU 400-210R
Switch rating 4 A @ 250 VAC
Poles Double‑pole (L & N)
Fusing Internal fuse (requires cover removal to access)
Indicator Neon mains‑on lamp (switched output)
Key operation Keylock actuator; key removable in ON & OFF
Label Usually marked 'FIRE ALARM — DO NOT SWITCH OFF'
Colour Typically red (400-210R); white version (400-210W) available where offered
Mounting Single‑gang enclosure; surface/backbox fit

Physical

Enclosure Single‑gang format
Dimensions INSUFFICIENT DATA
Material INSUFFICIENT DATA
Weight INSUFFICIENT DATA

Standards-&-approvals

Standards Manufacturer references use with BS5839 systems
Certification CE certificate/datasheet available from manufacturer (see datasheet)
Installation note Fit by qualified electrician; follow local regulations

Fire Alarm Mains Isolator (4A, Keylock) features

T2 Solutions 400-210R Fire Alarm Safety Isolator Switch, Red

Zeta / T2 Mains Safety Isolator Switch 400-210R, Keylock Double-Pole 4A

Introduction to the Zeta / T2 400-210R Mains Safety Isolator Switch

Zeta / T2 400-210R Mains Safety Isolator Switchis a purpose-built, tamper-resistant local isolator designed for use with fire alarm control and indicating equipment (CIE). It combines simple, robust switching with a keylock actuator, an internal fuse and a neon mains-on indicator to provide a secure, clearly identifiable isolation point for maintenance and emergency procedures. Typically supplied in a red single-gang enclosure and labelled for fire alarm use, this isolator is intended for professional installation where controlled access and clear identification are important.

Key features at a glance

  • Double-pole isolation:switches both Live and Neutral for safer local isolation of fire alarm mains.
  • 4 A @ 250 VAC rating:suitable for typical fire alarm control equipment loads.
  • Keylock actuator:key removable in both ON and OFF positions to prevent unauthorised switching.
  • Integral internal fuse:protects the switched circuit; access requires cover removal to discourage casual tampering.
  • Neon indicator:shows mains present at the switched output so status is easily visible.
  • Single-gang format:surface or backbox mounting in a compact, red enclosure for immediate recognition.

Detailed specifications and benefits

  • Model / SKU:400-210R
  • Switch rating:4 A @ 250 VAC
  • Poles:Double-pole (L & N)
  • Fusing:Internal fuse (requires cover removal to access)
  • Indicator:Neon mains-on lamp (switched output)
  • Key operation:Keylock actuator; key removable in ON & OFF positions
  • Label:Usually marked "FIRE ALARM — DO NOT SWITCH OFF"
  • Colour:Typically red (400-210R); white version (400-210W) may be available
  • Mounting:Single-gang enclosure for surface or backbox fit
  • Enhanced safety through double-pole switching:By isolating both Live and Neutral conductors, the isolator reduces the chance of accidental energisation of the circuit during maintenance and provides a safer local disconnect compared with single-pole switches that leave the neutral connected.
  • Controlled access with keylock:The keylock actuator prevents unauthorised or accidental switching of the fire alarm mains. Because the key is removable in both ON and OFF positions, authorised personnel can secure the isolator in the required state during work.
  • Clear status via neon indicator:The neon lamp gives an immediate visual cue when mains are present at the switched output — useful for engineers and building staff to verify power status without removing covers or using test equipment.
  • Tamper-resistant fusing:The internal fuse is not accessible without removing the cover, reducing the risk of inappropriate fuse changes on site which could compromise system protection or compliance.
  • Compliance-ready labelling and colour:The red enclosure and common labelling practice make it easy to identify the isolator as dedicated to fire alarm systems, supporting site protocols and emergency procedures.

Use cases and scenarios where this product excels

The primary application is immediate isolation adjacent to fire alarm control and indicating equipment. Installers typically fit the switch close to the control panel so authorised engineers can isolate mains power locally for safe maintenance or fault diagnosis without disturbing other building supplies.

In offices, schools, hospitals and retail environments where access needs to be controlled and downtime minimised, the keylock isolator enables technicians to lock the switch while they carry out work and then return it to normal operation. The visible neon indicator speeds troubleshooting by confirming whether the panel is receiving mains.

Sites with multiple technical services benefit from a dedicated, clearly labelled red isolator for the fire alarm. Security-sensitive locations — such as airports, data centres or critical infrastructure buildings — often require lockable isolators to ensure only authorised personnel can cut power to detection or alarm systems.

During commissioning of a new fire alarm installation or when carrying out periodic testing, the internal fuse and keylock help maintain site safety and compliance by preventing non‑qualified staff from interfering with the isolator.

Comparisons with similar products on the market

Standard non-keylock isolators are often cheaper and simpler but do not provide controlled access. For fire alarm applications where unauthorised switching could endanger building occupants or interrupt life-safety systems, the Zeta keylock model is the preferred choice because it prevents casual or malicious operation.

Single-pole isolators disconnect only the live conductor. The Zeta / T2’s double-pole design isolates both live and neutral, providing a safer condition for service personnel and reducing residual energisation risks. For fire alarm CIEs, double-pole switching is commonly recommended or required by good practice.

The internal fuse in the 400-210R provides local protection for the switched circuit. Some isolators are unfused, leaving upstream protection to breakers or fuses in distribution boards. The integrated fuse is convenient and appropriate for typical alarm panel loads, but installers should always verify correct fuse value and accessibility practices against site policy and regulations.

The 4 A rating suits most fire alarm panels and associated ancillary equipment. For large panels, power supplies, or installations with higher inrush currents, higher rated isolators (e.g. 10 A, 16 A or more) may be necessary. Choose the isolator rating to match the continuous and peak currents of the equipment it serves.

Customer feedback and testimonials

No verified customer testimonials are supplied with this product record. Typical feedback from installers who use lockable, double-pole isolators in fire alarm applications often highlights the following themes:

  • "Peace of mind": controlled access and tamper resistance reduce the likelihood of accidental shutdowns.
  • "Easy identification": the red enclosure and FIRE ALARM labelling help site teams quickly locate the isolation point during emergencies.
  • "Convenient status check": the neon indicator is repeatedly called out as a useful feature for quick visual verification of mains presence.

If you require real customer reviews for procurement or marketing purposes, ask the supplier for references or look for installer feedback forums and trade reviews where the model is discussed.

Compliance, installation and practical notes

The manufacturer references compatibility with BS5839 fire alarm systems and supplies CE documentation. Always consult the product datasheet and local regulations before specifying or installing. Key points:

  • Fit by a qualified electrician or approved fire alarm technician.
  • Label clearly (commonly "FIRE ALARM — DO NOT SWITCH OFF").
  • Do not switch off except by authorised personnel; follow site safety procedures and permit-to-work systems.
  • Confirm fuse rating and replace with the correct type if required — note the internal fuse is not accessible without removing the cover.
  • Check that the 4 A rating is adequate for the particular panel or load being isolated; specify a higher-rated isolator if necessary.
  • No warranty information is provided in the product record — verify warranty and after-sales support with the supplier.

Pricing and commercial considerations

The product record lists a cost price of 15.36 (currency unspecified) and a suggested retail price of 18.29, reflecting a circa 16% minimum gross margin calculation. When preparing final pricing for customers, confirm the currency, consider VAT or other taxes, freight and handling, and any additional labour or commissioning costs.

Conclusion — why choose the Zeta / T2 400-210R

The Zeta / T2 400-210R Mains Safety Isolator Switch is well suited to controlled fire alarm installations where safety, identification and restricted access are priorities. Its double-pole switching, keylock actuator, internal fuse and neon indication deliver a practical combination of protection and usability. For most standard fire alarm panels and small ancillary loads, the 4 A rating is appropriate; however, installers should always confirm load requirements and local standards before specifying any isolator.

In short, choose the 400-210R when you need a compact, site-friendly, lockable isolator dedicated to fire alarm equipment — particularly where visible status, tamper resistance and clear identification are required. For larger loads or non-fire alarm applications, compare ratings and formats to ensure the correct device for the job.

T2 Solutions 400-210R Fire Alarm Safety Isolator Switch, Red
Dynamic CCTV New

Zeta / T2 Mains Safety Isolator Switch 400-210R, Keylock Double-Pole 4A

£13.70 £16.64

Zeta / T2 400-210R Mains Safety Isolator Switch — tamper‑resistant, key‑operated local isolator for fire alarm control and indicating equipment. Designed for professional installations where a secure, lockable local isolation point is required for maintenance and safety.

Where this is used: Installed adjacent to fire alarm control and indicating equipment (CIE) to permit safe isolation for maintenance or servicing. Labelled "FIRE ALARM — DO NOT SWITCH OFF" in line with common site practice.

Compliance & safety: Manufacturer references CE documentation and cites compatibility with BS5839 installations — consult the manufacturer datasheet and local regulations before installation. Must be installed by a qualified electrician. Do not switch off except by authorised personnel; observe all site safety procedures.

Note on pricing: Cost price provided = 15.36 (currency not specified). Suggested price shown on this record assumes a 16% minimum gross margin and uses the numeric cost value supplied; confirm currency and whether prices should include VAT or other tax for final RRP.