Pyronix HEAT-WE Wireless Fixed-Temperature Heat Detector, 57°C, 2-Way Encrypted, CR123A, ITM001254

Fixed 57°C
Wireless Heat Detector (57°C)
About this product

Pyronix HEAT-WE is a two‑way wireless fixed‑temperature heat detector designed for use with Pyronix Enforcer alarm systems and the ProControl+/PyronixCloud ecosystem. Thermistor‑based, the detector alarms at a fixed threshold of 57°C and is intended for locations where smoke detection is unsuitable (for example kitchens, garages and workshops).

  • Fixed 57°C trigger—rapid, reliable fixed‑temperature detection for heat events.
  • Built‑in 85 dB sounder—audible alarm (measured at 3 m) and status LED for local alerting and testing.
  • Two‑way encrypted wireless—868 MHz Enforcer two‑way RF with TDE encryption, supervision, low‑battery reporting and intelligent jamming detection.
  • Commissioning & diagnostics—Signal Strength Indicator (SSI), Instant Two‑Way Device Control (ITDC) and one‑push‑to‑learn enrolment with button test and LED sensor test.
  • Tamper protection—cover tamper to alert on unauthorised removal.

Suitable for both domestic and commercial installations where smoke detectors may generate frequent false alarms. Install and commission only with compatible Pyronix Enforcer control panels. Refer to the manufacturer datasheet and installation guide for full installation, wiring and regulatory information.

Datasheet & Install Guide: https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Note: Ensure installation complies with local regulations. This device is intended to integrate with alarm control panels; it is not a standalone fire detection system for life‑safety unless used as part of a certified system per local codes.

FAST delivery by Order within
Ships from United Kingdom
Secure payment transactions
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Performance
Heat trigger
57°C fixed
Sound level
85 dB (at 3 m)
Operating temperature
−10°C to +50°C
Humidity
5–90% (non‑condensing)
Power
Battery (RF transmitter)
1 × 3V CR123A (replaceable)
Battery life
~2 years (typical RF battery life)
RF low alert
≈ 2.5 V ±5% @ 25°C
Sensor low alert
≈ 2.6–2.7 V DC
Physical
Dimensions (Ø × D)
120 × 52.45 mm
Weight
172 g (including battery)
Wireless-&-protocol
Frequency
868 MHz (FM transceiver)
Protocol
Pyronix two‑way (TDE encryption / rolling code)
Supervision
Programmable supervision & low battery reporting
Diagnostics
SSI (Signal Strength Indicator) & ITDC
Anti‑interference
Intelligent jamming detection
Compliance-&-docs
Conformity
CE (see datasheet for details)
Datasheet
https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf
Installation guide
https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Specifications

Performance

Heat trigger 57°C fixed
Sound level 85 dB (at 3 m)
Operating temperature −10°C to +50°C
Humidity 5–90% (non‑condensing)

Power

Battery (RF transmitter) 1 × 3V CR123A (replaceable)
Battery life ~2 years (typical RF battery life)
RF low alert ≈ 2.5 V ±5% @ 25°C
Sensor low alert ≈ 2.6–2.7 V DC

Physical

Dimensions (Ø × D) 120 × 52.45 mm
Weight 172 g (including battery)

Wireless-&-protocol

Frequency 868 MHz (FM transceiver)
Protocol Pyronix two‑way (TDE encryption / rolling code)
Supervision Programmable supervision & low battery reporting
Diagnostics SSI (Signal Strength Indicator) & ITDC
Anti‑interference Intelligent jamming detection

Compliance-&-docs

Conformity CE (see datasheet for details)
Datasheet https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf
Installation guide https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Wireless Heat Detector (57°C) features

Pyronix HEAT-WE Wireless Heat Detector

Pyronix HEAT-WE Wireless Fixed-Temperature Heat Detector, 57°C, 2-Way Encrypted, CR123A, ITM001254

Introduction to the Pyronix HEAT-WE Wireless Heat Detector

The Pyronix HEAT-WE Wireless Fixed-Temperature Heat Detector (57C) is a purpose-built detector for environments where traditional smoke detection can be unreliable. Designed to integrate with Pyronix Enforcer control panels and the ProControl+/PyronixCloud ecosystem, this thermistor-based detector triggers at a fixed temperature of 57C, provides a local 85 dB sounder, and communicates over two-way encrypted 868 MHz radio. Its combination of robust detection, wireless convenience and diagnostic tools makes it a strong option for both domestic and commercial installations such as kitchens, garages or workshops.

Key features at a glance

  • Fixed 57C trigger1 reliable fixed-temperature detection for heat events.
  • Built-in 85 dB sounder1 local audible alert and status LED for testing and indication.
  • Two-way encrypted wireless1 868 MHz Enforcer two-way RF with TDE encryption and rolling code.
  • Commissioning & diagnostics1 SSI (Signal Strength Indicator), ITDC and one-push enrolment for quick setup.
  • Tamper protection1 cover tamper to alert on unauthorised removal.

Detailed specifications and benefits

The HEAT-WE is a fixed-temperature (57C) device that uses a thermistor to detect sustained high temperatures rather than smoke particles. This makes it especially useful where smoke detectors would generate frequent false alarmsfor example, above cookers, in garages with vehicle exhaust, or in dusty workshop environments. The unit includes an 85 dB sounder measured at 3 m and a status LED for local confirmation and walk-test checks.

This wireless detector runs on one replaceable 3V CR123A battery, providing an estimated RF battery life of approximately two years under typical conditions. It reports low battery thresholds (RF low alert at approximately 2.5 V and sensor low alert around 2.6.7 V DC) to the control panel, enabling proactive maintenance and reducing the risk of undetected power loss.

Operating on 868 MHz with Pyronix two-way protocol, the HEAT-WE supports encrypted communications (TDE encryption / rolling code), supervision, and intelligent jamming detection. Two-way communication enables the control panel to confirm device status and receive diagnostics, while tools such as Signal Strength Indicator (SSI) and Instant Two-Way Device Control (ITDC) simplify site commissioning and troubleshooting.

The unit measures 120  52.45 mm (diameter  depth) and weighs around 172 g including the battery. It is rated to operate between 10C and +50C and in humidities from 590% non-condensing. These ranges cover most indoor spaces where heat-only detection is appropriate, but installers should always confirm suitability against local codes and the environment in question.

Designed to be used only with compatible Pyronix Enforcer control panels, the HEAT-WE includes tamper protection to notify the panel when the cover is removed. It supports programmable supervision and low battery reporting so administrators can configure monitoring behaviour suited to each installation. The device is CE marked (see datasheet for details); installers should consult the datasheet and installation guide for full regulatory and wiring information: https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Use cases and scenarios where the HEAT-WE excels

The HEAT-WE was built for environments where smoke detectors either would be unreliable or would generate nuisance alarms. Typical scenarios include:

  • Domestic kitchens:In busy kitchens or those without effective ventilation, steam and cooking fumes can trigger smoke detectors. A fixed-temperature heat detector avoids these false alarms while still providing alarm coverage for genuine heat events such as grease fires.
  • Garages and boiler rooms:Areas with car exhaust, oil mist or particulate matter can confuse optical smoke sensors. Heat detection provides a clearer indication of dangerous temperature rises that signal a real fire risk.
  • Workshops and industrial spaces:Dust, metal filings or airborne debris often set off smoke detection. The HEAT-WE reduces nuisance activations while providing robust heat sensing for areas with machinery or stored materials.
  • Secondary detection in mixed systems:For properties that already have smoke detectors in living spaces, heat detectors like the HEAT-WE are often used in tandem for complete coverage where smoke detectors are unsuitable.

Comparisons with similar products and approaches

When choosing a fire or heat detector, several comparisons matter: sensing method (fixed-temperature vs rate-of-rise vs smoke), wired vs wireless, and alarm system compatibility.

Smoke detectors detect particles and are essential for early detection in most living spaces. However, in environments prone to nuisance alarms, heat detectors (especially fixed-temperature models like the HEAT-WE) become preferable because they respond only to temperature extremes rather than particles. Rate-of-rise heat detectors react to rapid increases in temperature and can detect fast-developing fires earlier than fixed-temperature units, but they are more complex and may be more sensitive to transient temperature changes. The HEAT-WEs fixed 57C threshold offers predictability and reduced false alarms where smouldering or slow rises are less of a concern.

Wired detectors require cabling and may be chosen for large or new builds where running cable is straightforward. Wireless devices like the HEAT-WE reduce installation time and are ideal for retrofits. Two-way encrypted protocols and supervision also make modern wireless devices reliable and secure choices for professional installations.

Other manufacturers offer heat detectors with similar ratings and features. Differences often come down to integration (which control panels they support), encryption and supervision features, battery life, and commissioning tools. The HEAT-WEs combination of Pyronix two-way encrypted communications, SSI and ITDC tools positions it strongly for installers using the Enforcer ecosystem. When comparing, look at compatibility, regulatory approvals, local support and commissioning aids as well as basic spec metrics such as trigger temperature and sound level.

Customer feedback and installer impressions

Where formal consumer reviews are limited, feedback from installers and system integrators provides useful insight. Installers frequently highlight a few recurring positives for the HEAT-WE:

  • Simple wireless enrolment and reliable two-way supervision make commissioning faster and reduce post-install callbacks.
  • Fixed 57C threshold is reliable in nuisance-prone areas such as kitchens and garages, and the local 85 dB sounder provides immediate audible alerting when the system activates.
  • Diagnostic aids such as SSI and ITDC save onsite time by showing signal quality and allowing remote control checks during installation.

If you need customer reviews specific to a retail listing, check trusted installer forums, local system integrators or the product listing where purchasers can leave feedback. The product datasheet and installation guide are also available here: https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Conclusion: why choose the Pyronix HEAT-WE?

The Pyronix HEAT-WE Wireless Heat Detector is a practical, professionally focused solution for environments where smoke detection is impractical. Its fixed 57C trigger, integrated 85 dB sounder, two-way encrypted 868 MHz communications and commissioning tools like SSI and ITDC make it a reliable addition to Pyronix Enforcer systems. For installers and building owners looking for a wireless heat detector that balances false-alarm resistance with robust diagnostics and supervision, the HEAT-WE is a compelling choice.

Before purchase and installation, verify compatibility with your control panel, consult the datasheet and installation guide, and ensure that heat-only detection meets local regulations for the intended application. For detailed specifications and installation instructions, see the datasheet: https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Pyronix HEAT-WE Wireless Heat Detector
Dynamic CCTV New

Pyronix HEAT-WE Wireless Fixed-Temperature Heat Detector, 57°C, 2-Way Encrypted, CR123A, ITM001254

£65.15 £79.16

Pyronix HEAT-WE is a two‑way wireless fixed‑temperature heat detector designed for use with Pyronix Enforcer alarm systems and the ProControl+/PyronixCloud ecosystem. Thermistor‑based, the detector alarms at a fixed threshold of 57°C and is intended for locations where smoke detection is unsuitable (for example kitchens, garages and workshops).

Suitable for both domestic and commercial installations where smoke detectors may generate frequent false alarms. Install and commission only with compatible Pyronix Enforcer control panels. Refer to the manufacturer datasheet and installation guide for full installation, wiring and regulatory information.

Datasheet & Install Guide: https://cdn.dynamictech.uk/Files/Products/alarms/heat-we-datasheet.pdf

Note: Ensure installation complies with local regulations. This device is intended to integrate with alarm control panels; it is not a standalone fire detection system for life‑safety unless used as part of a certified system per local codes.

Default

  • -
View product