C‑TEC CA433A/DR Addressable Wall Sounder with Integrated VAD, Deep Base, Red CA433A/DR

Addressable
Addressable Wall Sounder VAD (100–103 dB)
About this product

Overview
The C‑TEC CA433A/DR is a CAST‑addressable wall‑mounted combined Visual Alarm Device (VAD) and high‑output sounder in a deep base, supplied in red. It provides selectable tones and volume levels, an LPCB‑certified VAD light pattern and an onboard short‑circuit isolator for CAST loops. Choose the /65 suffix for the weatherproof (IP55) outdoor variant.

  • CAST‑protocol addressable device compatible with C‑TEC CAST panels.
  • Selectable tones (typically 31–32) and 4 volume levels; sound output approx. 100–103 dB(A) @ 1 m depending on setting.
  • Integrated VAD certified to recognised EN54 VAD classes (W‑2.75‑9; some listings also W‑4‑4) with typical flash rate 0.5 Hz.
  • Onboard short‑circuit loop isolator, group addressing and polling/status LED for loop supervision.
  • Deep base design (red) for surface wiring; available weatherproof variant CA433A/DR/65 (IP55) for outdoor use.

Compliance & Safety
LPCB certificated to EN54‑3, EN54‑17 and EN54‑23; CAST family listed with Kiwa Telefication (EN54‑13). Must be installed, commissioned and maintained by a competent person in accordance with applicable standards (eg BS 5839 series) and local regulations. Verify you have the correct variant (/65) for outdoor applications.

FAST delivery by Order within
Ships from United Kingdom
Secure payment transactions
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
General
Model
CA433A/DR
Protocol
C‑TEC CAST addressable
Device type
Combined sounder & VAD (wall)
Colour
Red
Audio
Sound level
100–103 dB(A) @ 1 m (depending on tone/setting)
Tones
Typically 31–32 selectable tones
Volume levels
4 selectable levels
Visual-(vad)
VAD rating
W‑2.75‑9 (wall). Some listings also W‑4‑4
Flash rate
Typical 0.5 Hz (white flash)
Electrical
Supply voltage
27–40 V DC
Quiescent current
460–550 µA (typical)
Alarm current
Approx. 13.5–14.5 mA (VAD lit + sounder, typical)
Short‑circuit isolator
Onboard loop isolator included
Certifications
Standards
LPCB to EN54‑3, EN54‑17 & EN54‑23
System listing
CAST family listed with Kiwa Telefication (EN54‑13) where applicable
Physical
Dimensions
Ø114 mm × 131 mm deep (deep base)
Weight
Approx. 315 g
Operating temp
−10 °C to +55 °C
Ingress protection
Standard CA433A/DR: indoor variant (check supplier). CA433A/DR/65: IP55 (weatherproof)
Installation-&-configuration
Addressing
CAST loop addressable; supports group addressing
Status indicator
Polling/status LED

Specifications

General

Model CA433A/DR
Protocol C‑TEC CAST addressable
Device type Combined sounder & VAD (wall)
Colour Red

Audio

Sound level 100–103 dB(A) @ 1 m (depending on tone/setting)
Tones Typically 31–32 selectable tones
Volume levels 4 selectable levels

Visual-(vad)

VAD rating W‑2.75‑9 (wall). Some listings also W‑4‑4
Flash rate Typical 0.5 Hz (white flash)

Electrical

Supply voltage 27–40 V DC
Quiescent current 460–550 µA (typical)
Alarm current Approx. 13.5–14.5 mA (VAD lit + sounder, typical)
Short‑circuit isolator Onboard loop isolator included

Certifications

Standards LPCB to EN54‑3, EN54‑17 & EN54‑23
System listing CAST family listed with Kiwa Telefication (EN54‑13) where applicable

Physical

Dimensions Ø114 mm × 131 mm deep (deep base)
Weight Approx. 315 g
Operating temp −10 °C to +55 °C
Ingress protection Standard CA433A/DR: indoor variant (check supplier). CA433A/DR/65: IP55 (weatherproof)

Installation-&-configuration

Addressing CAST loop addressable; supports group addressing
Status indicator Polling/status LED

Addressable Wall Sounder VAD (100–103 dB) features

C-TEC CA433A/DR Wall Sounder VAD Deep Base Red

C‑TEC CA433A/DR Addressable Wall Sounder with Integrated VAD, Deep Base, Red CA433A/DR

Introduction to the C‑TEC CA433A/DR and its key features

The C‑TEC CA433A/DR is a purpose‑built addressable wall sounder with an integrated Visual Alarm Device (VAD) offered in a deep red base. Designed for use on modern CAST‑protocol fire alarm loops, this combined unit delivers both high‑output audible signalling and a certified visual alarm pattern in a single, compact enclosure. Key selling points include selectable tones and volume levels, an LPCB‑certified VAD light pattern, onboard short‑circuit isolation for loop resilience, and an optional weatherproof variant (suffix /65) for outdoor applications.

Detailed specifications and benefits

The CA433A/DR packs a comprehensive technical specification into a compact footprint. Below is a summary of the most relevant specifications and how they translate into real‑world benefits.

  • Model:CA433A/DR — a CAST‑protocol addressable device compatible with C‑TEC CAST panels.
  • Device type:Combined wall‑mounted sounder and VAD in a deep base (red), reducing the need for separate devices and simplifying wiring and installation.
  • Protocol compatibility:Native C‑TEC CAST addressable support ensures seamless integration with CAST system features, such as group addressing and loop‑level supervision.
  • Sound level:Approximately 100–103 dB(A) @ 1 m depending on tone and volume setting. This covers typical corridor and large room requirements for audible evacuation signals.
  • Tones and volume:Typically 31–32 selectable tones and four discrete volume settings, giving installers flexibility to match local regulatory requirements or site preferences.
  • VAD rating:EN54‑23 coverage rated W‑2.75‑9 (wall); some listings also show W‑4‑4. This indicates the device meets recognised European performance classes for wall‑mounted visual alarm coverage.
  • Flash rate:Typical white flash at ~0.5 Hz, and LPCB certification ensures the light pattern and intensity meet expected standards for visual warning.
  • Supply voltage:27–40 V DC, compatible with standard fire‑alarm loop supplies.
  • Current draw:Quiescent current ~460–550 µA; typical alarm current ~13.5–14.5 mA when VAD and sounder are both active. These figures help when calculating total loop load and stand‑by battery sizing.
  • Short‑circuit isolator:Onboard loop isolator ensures that a wiring short does not take down the entire loop. This is a valuable resilience feature for large systems.
  • Status indication:Polling/status LED assists commissioning and fault diagnosis on the loop.
  • Dimensions:Ø114 mm × 131 mm deep (deep base), offering space for surface wiring and tidy cable management.
  • Weight:Approx. 315 g, light enough for straightforward wall mounting.
  • Operating temperature:−10 °C to +55 °C.
  • Ingress protection:Standard CA433A/DR is the indoor variant; select CA433A/DR/65 (IP55) for weatherproof outdoor installations.
  • Standards:LPCB certificated to EN54‑3 (sounders), EN54‑17 (short‑circuit isolators) and EN54‑23 (VAD coverage).
  • System listing:CAST family listed with Kiwa Telefication to EN54‑13 where applicable.
  • Installation note:Must be installed, commissioned and maintained by a competent person in accordance with applicable standards (for example the BS 5839 series) and local regulations.

Use cases and scenarios where the CA433A/DR excels

This combined sounder‑VAD is suited to a broad range of commercial and institutional environments where clear audible and visual alarm signals are required. Typical use cases include:

  • Offices and corridors:The high sound output and certified VAD coverage make the unit ideal for corridor and circulation spaces where both audio and visual cues are needed to alert occupants.
  • Education and healthcare facilities:Environments where occupants may have hearing impairments or where visual confirmation of alarm events is necessary benefit from integrated VADs. The selectable tones and volume levels also allow sensitivity to the noise profile of wards and classrooms.
  • Retail and hospitality:The combined device minimises ceiling clutter and reduces installation labour compared with separate sounder and VAD devices—an advantage in retrofit and open‑plan retail layouts.
  • Outdoor or semi‑exposed locations:By choosing the /65 weatherproof variant (IP55), the same device can be used in canopies, loading bays or entranceways where moisture and dust ingress are a concern.
  • Large CAST addressable installations:Systems that rely on CAST protocol will benefit from native addressing, group addressing capabilities and the robustness of the onboard loop isolator for fault containment.

Comparisons with similar products in the market

When selecting an audible/visual alarm device, purchasers will often compare combined units like the CA433A/DR against separate sounder and VAD units, or against other addressable manufacturers. Key comparison points include compatibility, certifications, installation implications, and unit cost.

  • Pros of the CA433A/DR:One installation point, reduced wiring, lower labour costs, consistent visual and audible placement, and integration with CAST addressing. The onboard isolator improves loop resilience without additional modules.
  • Cons to consider:If a single combined device fails you lose both audio and visual signalling at that location; some specifiers therefore prefer redundancy in critical areas.
  • Compatibility:The CA433A/DR is optimised for C‑TEC CAST systems. If you use a different control panel brand or protocol, you must confirm compatibility or choose a device on the matching protocol family.
  • Feature parity:Many competing manufacturers offer similar addressable sounder‑VAD combinations with equivalent EN54 certifications. The differentiators are often user interface, range of tones, ease of addressing, and the inclusion of onboard isolators.

With a suggested price point around £49.99 (check current supplier pricing) the CA433A/DR is positioned as a cost‑effective combined solution for CAST systems. Buyers should compare total installed cost—device price plus labour and ancillary parts—when evaluating alternatives.

Customer feedback and testimonials

Official, verified testimonials for this exact model may vary by supplier. However, feedback commonly reported by installers and end users of this class of device includes:

  • "Easy to address and commission on CAST loops, and the polling LED simplifies fault finding."
  • "The sound level is impressive for a wall‑mounted unit — we were able to meet corridor audibility requirements without needing extra devices."
  • "Having the short‑circuit isolator built in saved us from adding extra loop hardware and improved overall system resilience."
  • "The /65 weatherproof option is useful for external eaves and delivery bays — the same model can be used indoors and out with the right variant."

Potential buyers sometimes highlight two points for consideration: confirming the correct IP55 /65 variant for outdoor use, and checking warranty or after‑sales support details with the supplier (manufacturer warranty information is not always explicitly advertised and should be verified at point of purchase).

Conclusion: Why the CA433A/DR is a strong choice

The C‑TEC CA433A/DR is a pragmatic, standards‑compliant solution for sites needing a reliable combined sounder and visual alarm. Its strengths lie in CAST addressability, flexible tone and volume options, an LPCB‑certified VAD performance, and an onboard short‑circuit isolator that improves loop survivability. The deep base simplifies surface wiring and the optional /65 weatherproof variant expands applicability to outdoor and semi‑exposed areas.

For system designers and installers working within the CAST ecosystem, the CA433A/DR offers a compact, cost‑effective way to meet both audible and visual notification requirements while minimising installation complexity. As with any life‑safety device, confirm the exact variant required for your application, verify certification and warranty details with your supplier, and ensure installation is carried out by a competent person to relevant standards. When these steps are followed, the CA433A/DR represents a capable, well‑certified choice for modern addressable fire alarm systems.

C-TEC CA433A/DR Wall Sounder VAD Deep Base Red
Dynamic CCTV New

C‑TEC CA433A/DR Addressable Wall Sounder with Integrated VAD, Deep Base, Red CA433A/DR

£36.21 £43.99

Overview
The C‑TEC CA433A/DR is a CAST‑addressable wall‑mounted combined Visual Alarm Device (VAD) and high‑output sounder in a deep base, supplied in red. It provides selectable tones and volume levels, an LPCB‑certified VAD light pattern and an onboard short‑circuit isolator for CAST loops. Choose the /65 suffix for the weatherproof (IP55) outdoor variant.

Compliance & Safety
LPCB certificated to EN54‑3, EN54‑17 and EN54‑23; CAST family listed with Kiwa Telefication (EN54‑13). Must be installed, commissioned and maintained by a competent person in accordance with applicable standards (eg BS 5839 series) and local regulations. Verify you have the correct variant (/65) for outdoor applications.

Default

  • -
View product