Texecom Premier Compact IR PIR Motion Detector, 12 m Volumetric, 90°, ACD-0001

12m Range
Premier Compact PIR (12 m)
About this product

Texecom Premier Compact IR (ACD-0001) is a wired, wall/ceiling passive‑infrared (PIR) motion detector designed for indoor intruder alarm installations. Its sealed Fresnel optics, selectable pulse‑count sensitivity and digital temperature compensation reduce false alarms while providing reliable volumetric detection up to 12 m with 90° coverage. The unit includes built‑in end‑of‑line (EOL) resistors, tamper monitoring and a normally‑closed alarm relay for direct connection to wired control panels.

  • 12 m volumetric detection range with 90° coverage for indoor protection
  • Sealed Fresnel lens and analogue signal processing to reduce environmental effects
  • Selectable pulse‑count sensitivity and digital temperature compensation to improve false‑alarm immunity
  • Built‑in EOL resistors, removable terminal block and tamper monitoring for straightforward installation
  • Compact, low‑profile housing (95 × 63 × 40.5 mm) suitable for domestic and commercial use
  • Meets recognised intruder detector standards (PD6662 / EN50131 Grade 2 / Class II as marketed)

Typical use cases: domestic and small commercial intruder detection, retrofit and new builds where a compact, low‑profile volumetric PIR is required. Installation notes: mount between 1.5 m and 3.1 m for optimal coverage; avoid direct sunlight, air‑conditioning vents and heat sources that face the lens. Follow the manufacturer datasheet and applicable UK installation standards; ensure wiring and commissioning is carried out by a qualified installer where required.

Ships from United Kingdom
Secure payment transactions
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Detection
Type
Passive IR (PIR)
Detection range
12 m
Detection angle
90°
Optics
Sealed Fresnel lens
Target speed
0.3–3.0 m/s
Signal processing
Analogue
Electrical
Supply voltage
9–15 V DC (nom. 12–15 V)
Normal current
Max 8.7 mA
Max current
Max 10.6 mA
Alarm current
Max 7.5 mA
Ripple tolerance
Peak‑to‑peak 2 V at 12 V DC
Outputs
Alarm relay
<24 V, 50 mA (NC), ≈34 Ω max resistive
Tamper output
<24 V, 50 mA (NC)
EOL resistors
Built‑in
Mechanical
Dimensions (H×W×D)
95 × 63 × 40.5 mm
Weight
≈73 g
Mounting height
1.5–3.1 m
Environmental
Operating temperature
−10 °C to +55 °C
Relative humidity
Max 95% (non‑condensing)
Compliance
Standards
Marketed to PD6662 / EN50131 (Grade 2 / Class II)

Specifications

Detection

Type Passive IR (PIR)
Detection range 12 m
Detection angle 90°
Optics Sealed Fresnel lens
Target speed 0.3–3.0 m/s
Signal processing Analogue

Electrical

Supply voltage 9–15 V DC (nom. 12–15 V)
Normal current Max 8.7 mA
Max current Max 10.6 mA
Alarm current Max 7.5 mA
Ripple tolerance Peak‑to‑peak 2 V at 12 V DC

Outputs

Alarm relay <24 V, 50 mA (NC), ≈34 Ω max resistive
Tamper output <24 V, 50 mA (NC)
EOL resistors Built‑in

Mechanical

Dimensions (H×W×D) 95 × 63 × 40.5 mm
Weight ≈73 g
Mounting height 1.5–3.1 m

Environmental

Operating temperature −10 °C to +55 °C
Relative humidity Max 95% (non‑condensing)

Compliance

Standards Marketed to PD6662 / EN50131 (Grade 2 / Class II)

Premier Compact PIR (12 m) features

Texecom ACD-0001 PIR Motion Detector

Texecom Premier Compact IR PIR Motion Detector, 12 m Volumetric, 90°, ACD-0001

Introduction: Texecom Premier Compact IR PIR (ACD-0001) — Key features at a glance

The Texecom Premier Compact IR PIR (ACD-0001) is a compact, wired passive‑infrared (PIR) motion detector engineered for reliable indoor intruder detection. Marketed as the Premier Compact PIR (12 m), this sensor delivers volumetric coverage up to 12 m with a 90° field of view, packed into a low‑profile housing. Designed for domestic and small commercial alarm systems, it combines sealed Fresnel optics, analogue signal processing, selectable pulse‑count sensitivity and digital temperature compensation to reduce false alarms while maintaining consistent detection performance.

Key selling points include built‑in end‑of‑line (EOL) resistors for simplified wiring, tamper monitoring, a normally‑closed alarm relay for direct panel connection, and compliance with recognised intruder detector standards (marketed to PD6662 / EN50131 Grade 2 / Class II). The unit’s physical footprint (95 × 63 × 40.5 mm) and light weight (≈73 g) make it suitable for new builds and retrofits where discretion and unobtrusive appearance matter.

Detailed specifications and benefits

  • Type: Passive IR (PIR) — reliable motion sensing using infrared energy changes.
  • Detection range: 12 m volumetric — covers medium‑sized rooms such as living rooms, offices and retail areas.
  • Detection angle: 90° — provides wide coverage when mounted on walls or corners.
  • Optics: Sealed Fresnel lens — minimizes the effect of dust and insects, extending consistent sensitivity over time.
  • Target speed: 0.3–3.0 m/s — tuned to detect typical human movement while ignoring very slow or very fast irrelevant events.
  • Signal processing: Analogue — smooths and interprets PIR signals to distinguish real motion from spurious changes.

Benefits: Together these detection characteristics offer dependable volumetric protection with a design focus on reducing nuisance alarms. The sealed Fresnel lens and analogue processing preserve sensitivity and lower maintenance needs compared with unsealed or purely digital lens designs.

  • Supply voltage: 9–15 V DC (nominal 12–15 V) — compatible with most wired alarm panels.
  • Current consumption: Normal max 8.7 mA; alarm max 7.5 mA; absolute max 10.6 mA — low power draw suitable for multi‑device systems.
  • Ripple tolerance: Peak‑to‑peak 2 V at 12 V DC — stable operation in typical installations.
  • Alarm relay: Normally closed (NC), <24 V, 50 mA — ready for hardwired connection to control panels without additional interface modules.
  • Tamper output: NC <24 V, 50 mA — provides enclosure tamper detection to alert on physical interference.
  • Built‑in EOL resistors — simplify wiring and meet panel expectations for supervised circuits.

Benefits: The integrated outputs and EOL resistors reduce installation time and potential wiring errors. Low current consumption helps maintain overall system efficiency and reduces battery drain on backup power supplies.

  • Dimensions: 95 × 63 × 40.5 mm — compact, low‑profile design that blends into interiors.
  • Weight: ≈73 g — light and easy to mount.
  • Mounting height: 1.5–3.1 m — flexible placement to optimise coverage.
  • Operating temperature: −10 °C to +55 °C; relative humidity: max 95% non‑condensing.
  • Compliance: Marketed to PD6662 / EN50131 (Grade 2 / Class II).

Benefits: The mechanical and environmental specifications make the detector suitable for most indoor environments, from domestic living spaces to small commercial offices and retail units. Compliance with industry standards gives installers confidence about performance expectations and regulatory alignment.

Use cases and scenarios where the Premier Compact PIR excels

The Premier Compact PIR is versatile and particularly well suited to scenarios that require reliable volumetric detection with a discreet form factor. Typical applications include:

  • Domestic intruder detection — living rooms, hallways, basements and garages where 12 m coverage and a wide 90° angle help detect unauthorised movement without multiple sensors.
  • Small commercial premises — offices, clinics, back‑of‑house rooms and small retail outlets benefit from a single sensor covering a medium room area.
  • Retrofit projects — the compact housing and built‑in EOL resistors reduce on‑site modifications, making upgrades simpler and cleaner.
  • New builds — easily integrated into wired alarm systems during construction with minimal aesthetic impact.
  • Multi‑sensor installations — as part of a layered strategy (door contacts, glass break, external detection), these PIRs provide interior volumetric coverage to complement perimeter sensors.

Installation guidance: for optimal performance, mount between 1.5 m and 3.1 m, avoid direct sunlight or aim at heating/ventilation outlets, and follow the manufacturer datasheet and applicable UK installation standards. Commissioning by a qualified installer ensures sensitivity and pulse‑count settings are tailored to the environment, reducing false alarms caused by pets, curtains or HVAC drafts.

Comparisons with similar products on the market

When selecting a PIR motion detector, installers and buyers compare detection range, false‑alarm immunity, physical size, installation features and cost. The Texecom Premier Compact IR positions itself as a value‑focused option with thoughtful design choices:

  • Versus basic domestic PIRs: Many low‑cost domestic sensors offer shorter ranges (6–8 m) or simpler optics. The 12 m range and sealed Fresnel lens of the Premier Compact give greater coverage and longer reliable service in dusty environments.
  • Versus premium multi‑technology detectors: Higher‑end detectors may combine PIR with microwave or dual‑technology sensing to further reduce false alarms, but they typically come at higher cost and complexity. The Premier Compact offers a balance — improved nuisance reduction via pulse‑count and temperature compensation without the extra price of dual‑tech units.
  • Versus other Texecom models: Compared with larger or feature‑rich models in the Texecom portfolio, the Premier Compact is more compact and economical, making it ideal where a low profile and straightforward performance are preferred.
  • Cost considerations: With a suggested retail price around £12.99 and a low cost price profile, this detector offers strong unit economics for installers deploying multiple sensors in a project while still delivering industry‑standard compliance and features.

Bottom line: If your priority is dependable volumetric coverage, low nuisance alarms and straightforward wiring at an attractive price point, the Premier Compact IR is a compelling choice. If you need highest‑end false‑alarm immunity in challenging environments (lots of drafts, reflective surfaces or rapid temperature swings), evaluate dual‑technology or advanced digital models alongside this PIR.

Customer testimonials and installer feedback

While individual customer experiences vary by environment and installation quality, common themes from installers and end users considering detectors like the Premier Compact IR are:

  • "Good coverage and easy to wire" — installers appreciate the built‑in EOL resistors and removable terminal block that speed up installation and reduce callbacks.
  • "Low profile and unobtrusive" — homeowners often prefer the small footprint and neutral styling that blends with interiors.
  • "Reliable in normal indoor environments" — users in domestic and small commercial scenarios typically report consistent detection without frequent false alarms when correctly sited and commissioned.

Note: These summarised comments reflect common feedback patterns for compact sealed‑lens PIR detectors. For verified testimonials specific to the Texecom Premier Compact IR, consult distributor product pages or speak with certified installers who have deployed the ACD‑0001 in comparable sites.

Conclusion: Why choose the Texecom Premier Compact IR PIR?

The Texecom Premier Compact IR (ACD‑0001) offers a pragmatic mix of coverage, reliability and installation simplicity. With 12 m volumetric range, 90° coverage, sealed Fresnel optics and features intended to reduce false alarms (pulse‑count sensitivity and digital temperature compensation), it addresses the core needs of domestic and small commercial intrusion detection. Built‑in EOL resistors, tamper monitoring and low current consumption streamline integration with wired alarm panels and help keep ongoing maintenance minimal.

For projects where unobtrusive appearance, consistent indoor performance and cost efficiency matter, this detector is a strong choice. It gives installers a dependable and familiar PIR option that meets recognised standards and integrates cleanly into a variety of alarm systems. If your site demands more advanced multi‑technology false‑alarm rejection, consider pairing or comparing the Premier Compact with dual‑technology detectors; otherwise, as a robust, compact PIR sensor, the ACD‑0001 balances price, performance and practicality effectively.

Suggested retail price: £12.99 (indicative). Warranty information: not specified — consult the supplier or Texecom documentation for current warranty and support details prior to purchase and installation.

Texecom ACD-0001 PIR Motion Detector
Dynamic CCTV New

Texecom Premier Compact IR PIR Motion Detector, 12 m Volumetric, 90°, ACD-0001

£7.58 £9.20

Texecom Premier Compact IR (ACD-0001) is a wired, wall/ceiling passive‑infrared (PIR) motion detector designed for indoor intruder alarm installations. Its sealed Fresnel optics, selectable pulse‑count sensitivity and digital temperature compensation reduce false alarms while providing reliable volumetric detection up to 12 m with 90° coverage. The unit includes built‑in end‑of‑line (EOL) resistors, tamper monitoring and a normally‑closed alarm relay for direct connection to wired control panels.

Typical use cases: domestic and small commercial intruder detection, retrofit and new builds where a compact, low‑profile volumetric PIR is required. Installation notes: mount between 1.5 m and 3.1 m for optimal coverage; avoid direct sunlight, air‑conditioning vents and heat sources that face the lens. Follow the manufacturer datasheet and applicable UK installation standards; ensure wiring and commissioning is carried out by a qualified installer where required.

Default

  • -
View product